|
|
|
Off-Line Thickness Gauging
 |
 |
Model CX-1000 Film Thickness Gauge
The CX-1000 combines our patented capacitance sensor with industry-leading software to give you plastic film thickness profiling resolution to one microinch. This gauge can be run as a stand-alone bench unit, or can be connected to a computer for RS-232 operation by our Model CX-1100 Quality Control Software. Capacitance measurement is industry-recognized as the best choice for off-line, high resolution, continuous gauge profiling for plastic films. |
|
 |
 |
Model CX-1020 AutoCalTM Film Thickness Gauge
The CX-1020 revolutionized capacitance film thickness gauging with the introduction of our patented AutoCalTM concept - by adding an absolute (contact) measurement probe with the capacitance sensor, the CX-1020 is self-calibrating. No more need to create detailed recipes to recall calibration information. Accidental operator errors are reduced, accuracy is increased, because different polymers and blends require different calibration values. |
|
 |
 |
Model MX-1210 MicroGaugeTM
The MX-1210 utilizes an LVDT sensor, contact foot and an isolated "C" frame assembly and resolves to ten millionths of an inch with accuracy to 20 microinches. Rugged and cost effective, the Microgauge can provide accurate measurement of caliper or thickness of paper, tissue and plastic films. Drive increments can be set for 1 to 6 inch steps (paper) or 0.20 to 4.0 inch steps (film) with other ranges available. Statistics are reported on the display on the faceplate, and the MX-1210 can operate our Model CX-1100 Quality Control Software.
Operational Video of the MX-1210 MicroGauge Caliper/Thickness Gauge:
MX-1210 MicroGauge Video
|
|
 |
 |
Model MX-1200 MicroGaugeTM
The MX-1200 utilizes an LVDT contact sensor, and an isolated "C" frame assembly which resolves to ten millionths of an inch with accuracy to 20 microinches. Measurement head automatically cycles up/down, with operator pulling samples underneath for up to 1024 readings per sample. Statistics reported on gauge display include high, low, average and standard deviation, and the MX-1200 can operate our Model CX-1100 Quality Control Software. |
|
 |
 |
Model MX-1100 MicroGaugeTM
Economical, Accurate, Easy-to-Operate... the MX-1100 utilizes an LVDT contact sensor, and proven "Isolated C Frame" and resolves to ten millionths of an inch with accuracy to 50 microinches. "True Cam" for accurate descent rates, and one-button "zeroing" are standard. Equipped with an RS-232 port for a serial printer or computer to allow operation with 3rd-party statistics and quality control software packages. Manufactured to meet TAPPI specifications for paper or ASTM specifications for film. Range: 40 mils (0.04 inch), available to 0.50 inch. |
|
 |
 |
Series XL-750 / 770 / 770-VF Bench Micrometers
Designed for high-performance thickness inspection of film and foil, these systems provide very high resolution and accuracy. Resolution to ten millionths of an inch with accuracy to 12.5 microinches. Air-actuated LVDT contact sensor allows variable gaging force settings. Proprietary "floating anvil" eliminates parallelism error. Push-button zero. |
|
 |
 |
Series 543 Bench Micrometers
Digital indicator and stand provides a convenient, cost-effective way to perform plant floor or laboratory spot checks of film and sheet thickness. Also ideal for tensile test sample thickness measurement. Resolution to 50 millionths of an inch with accuracy to 120 microinches. Glass scale technology is rugged and reliable. Can be connected to SPC software for statistical and graphical data analysis. 1.00 inch measuring range. Contact point matched to requirements of application. |
|
 |
 |
Series 7 & Series 547 Hand Micrometers
Hand micrometers provide a portable method for spot checks of film and sheet thickness. Offered in two styles: digital and dial-type. Digital thickness gauge offers 0.47 inch measuring range, 50 millionths of an inch resolution with accuracy with accuracy to 150 microinch. Battery operated with 5000 hour life. Dial thickness gauge (shown) offers 50 mil measuring range, 0.1 mil resolution and 0.2 mil accuracy. Rugged spring-loaded spindle. |
|
 |
 |
Model CX-1100 Quality Control Software for CX-1000 and CX-1020 Film Thickness Gauges and MX-1210 and MX-1200 MicroGauges
Oakland's CX-1100 Quality Control Software brings several advances to off-line thickness gauging control. In addition to a wide range of statistical and graphical information including linear / polar profile displays, statistics summaries, and advanced statistical and process analysis, data can be easily transferred to your in-house quality control systems. Multiple file overlays for before-and-after comparisons, end-to-end file combination capability, search/sort by various criteria, and many other application-specific functions make this an invaluable addition to your off-line film, tissue, or paper thickness gauge. |
|
 |
 |
Oakland adds Multi-layer Film Thickness Gauges to its Product Line to Measure Individual Layer Thickness Variation in Coextruded and Coated Films
See our Website tab labelled "News" for more information on this product line.
Oakland Instrument introduces the LayerGaugeTM line of thickness gauges by Davinor. Designed for precise measurement of individual layer thickness in coextruded films, with unsurpassed accuracy and resolution. Oakland also offers a complete line of accessories for your LayerGaugeTM, including microscope systems, layer measurement software, and sample preparation accessories to meet todays' demanding requirements for barrier and complex film structures.
Please contact the factory to discuss your application, and to request your free sample analysis thickness profile. |
|
|